Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
1.
Skeletal Radiol ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441617

RESUMO

Magnetic resonance imaging (MRI) is crucial for accurately diagnosing a wide spectrum of musculoskeletal conditions due to its superior soft tissue contrast resolution. However, the long acquisition times of traditional two-dimensional (2D) and three-dimensional (3D) fast and turbo spin-echo (TSE) pulse sequences can limit patient access and comfort. Recent technical advancements have introduced acceleration techniques that significantly reduce MRI times for musculoskeletal examinations. Key acceleration methods include parallel imaging (PI), simultaneous multi-slice acquisition (SMS), and compressed sensing (CS), enabling up to eightfold faster scans while maintaining image quality, resolution, and safety standards. These innovations now allow for 3- to 6-fold accelerated clinical musculoskeletal MRI exams, reducing scan times to 4 to 6 min for joints and spine imaging. Evolving deep learning-based image reconstruction promises even faster scans without compromising quality. Current research indicates that combining acceleration techniques, deep learning image reconstruction, and superresolution algorithms will eventually facilitate tenfold accelerated musculoskeletal MRI in routine clinical practice. Such rapid MRI protocols can drastically reduce scan times by 80-90% compared to conventional methods. Implementing these rapid imaging protocols does impact workflow, indirect costs, and workload for MRI technologists and radiologists, which requires careful management. However, the shift from conventional to accelerated, deep learning-based MRI enhances the value of musculoskeletal MRI by improving patient access and comfort and promoting sustainable imaging practices. This article offers a comprehensive overview of the technical aspects, benefits, and challenges of modern accelerated musculoskeletal MRI, guiding radiologists and researchers in this evolving field.

2.
Radiology ; 310(1): e230764, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38165245

RESUMO

While musculoskeletal imaging volumes are increasing, there is a relative shortage of subspecialized musculoskeletal radiologists to interpret the studies. Will artificial intelligence (AI) be the solution? For AI to be the solution, the wide implementation of AI-supported data acquisition methods in clinical practice requires establishing trusted and reliable results. This implementation will demand close collaboration between core AI researchers and clinical radiologists. Upon successful clinical implementation, a wide variety of AI-based tools can improve the musculoskeletal radiologist's workflow by triaging imaging examinations, helping with image interpretation, and decreasing the reporting time. Additional AI applications may also be helpful for business, education, and research purposes if successfully integrated into the daily practice of musculoskeletal radiology. The question is not whether AI will replace radiologists, but rather how musculoskeletal radiologists can take advantage of AI to enhance their expert capabilities.


Assuntos
Inteligência Artificial , Comércio , Humanos , Cintilografia , Exame Físico , Radiologistas
4.
Eur Radiol ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244046

RESUMO

OBJECTIVE: To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system. METHODS: This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger's kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings. RESULTS: Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1-88.8%) and trainees, 86.6% (95% CI 85.2-87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) (p = 0.036). CONCLUSION: Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system. CLINICAL RELEVANCE STATEMENT: The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists. KEY POINTS: • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).

5.
J Neuroimaging ; 34(1): 145-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37807097

RESUMO

BACKGROUND AND PURPOSE: To compare the accuracy of subjective Alberta Stroke Program Early CT Score (sASPECTS) evaluation and that of an automated prototype software (aASPECTS) on nonenhanced CT (NECT) in patients with early anterior territory stroke and controls using side-to-side quantification of hypoattenuated brain areas. METHODS: We retrospectively analyzed the NECT scans of 42 consecutive patients with ischemic stroke before reperfusion and 42 controls using first sASPECTS and subsequently aASPECTS. We assessed the differences in Alberta Stroke Program Early CT Score (ASPECTS) and calculated the sensitivity and specificity of NECT with CT perfusion, whereas cerebral blood volume (CBV) served as the reference standard for brain infarction. RESULTS: The clot was located in the middle cerebral artery (MCA) in 47.6% of cases and the internal carotid artery (ICA) in 28.6% of cases. Ten cases presented combined ICA and MCA occlusions. The stroke was right sided in 52.4% of cases and left sided in 47.6%. Reader-based NECT analysis yielded a median sASPECTS of 10. The median CBV-based ASPECTS was 7. Compared to the area of decreased CBV, sASPECTS yielded a sensitivity of 12.5% and specificity of 86.8%. The software prototype (aASPECTS) yielded an overall sensitivity of 65.5% and a specificity of 92.2%. The interreader agreement for ASPECTS evaluation of admission NECT and follow-up CT was almost perfect (κ = .93). The interreader agreement of the CBV color map evaluation was substantial (κ = .77). CONCLUSIONS: aASPECTS of NECT can outperform sASPECTS for stroke detection.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Encéfalo
7.
Skeletal Radiol ; 53(2): 209-244, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37566148

RESUMO

OBJECTIVE: Direct magnetic resonance arthrography (dMRA) is often considered the most accurate imaging modality for the evaluation of intra-articular structures, but utilization and performance vary widely without consensus. The purpose of this white paper is to develop consensus recommendations on behalf of the Society of Skeletal Radiology (SSR) based on published literature and expert opinion. MATERIALS AND METHODS: The Standards and Guidelines Committee of the SSR identified guidelines for utilization and performance of dMRA as an important topic for study and invited all SSR members with expertise and interest to volunteer for the white paper panel. This panel was tasked with determining an outline, reviewing the relevant literature, preparing a written document summarizing the issues and controversies, and providing recommendations. RESULTS: Twelve SSR members with expertise in dMRA formed the ad hoc white paper authorship committee. The published literature on dMRA was reviewed and summarized, focusing on clinical indications, technical considerations, safety, imaging protocols, complications, controversies, and gaps in knowledge. Recommendations for the utilization and performance of dMRA in the shoulder, elbow, wrist, hip, knee, and ankle/foot regions were developed in group consensus. CONCLUSION: Although direct MR arthrography has been previously used for a wide variety of clinical indications, the authorship panel recommends more selective application of this minimally invasive procedure. At present, direct MR arthrography remains an important procedure in the armamentarium of the musculoskeletal radiologist and is especially valuable when conventional MRI is indeterminant or results are discrepant with clinical evaluation.


Assuntos
Artrografia , Imageamento por Ressonância Magnética , Humanos , Artrografia/métodos , Radiografia , Imageamento por Ressonância Magnética/métodos , Ombro/diagnóstico por imagem , Punho
8.
Eur Radiol ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38062268

RESUMO

OBJECTIVES: Early, accurate diagnosis is crucial for the prognosis of patients with soft tissue sarcomas. To this end, standardization of imaging algorithms, technical requirements, and reporting is therefore a prerequisite. Since the first European Society of Musculoskeletal Radiology (ESSR) consensus in 2015, technical achievements, further insights into specific entities, and the revised WHO-classification (2020) and AJCC staging system (2017) made an update necessary. The guidelines are intended to support radiologists in their decision-making and contribute to interdisciplinary tumor board discussions. MATERIALS AND METHODS: A validated Delphi method based on peer-reviewed literature was used to derive consensus among a panel of 46 specialized musculoskeletal radiologists from 12 European countries. Statements were scored online by level of agreement (0 to 10) during two iterative rounds. Either "group consensus," "group agreement," or "lack of agreement" was achieved. RESULTS: Eight sections were defined that finally contained 145 statements with comments. Overall, group consensus was reached in 95.9%, and group agreement in 4.1%. This communication contains the first part consisting of the imaging algorithm for suspected soft tissue tumors, methods for local imaging, and the role of tumor centers. CONCLUSION: Ultrasound represents the initial triage imaging modality for accessible and small tumors. MRI is the modality of choice for the characterization and local staging of most soft tissue tumors. CT is indicated in special situations. In suspicious or likely malignant tumors, a specialist tumor center should be contacted for referral or teleradiologic second opinion. This should be done before performing a biopsy, without exception. CLINICAL RELEVANCE: The updated ESSR soft tissue tumor imaging guidelines aim to provide best practice expert consensus for standardized imaging, to support radiologists in their decision-making, and to improve examination comparability both in individual patients and in future studies on individualized strategies. KEY POINTS: • Ultrasound remains the best initial triage imaging modality for accessible and small suspected soft tissue tumors. • MRI is the modality of choice for the characterization and local staging of soft tissue tumors in most cases; CT is indicated in special situations. Suspicious or likely malignant tumors should undergo biopsy. • In patients with large, indeterminate or suspicious tumors, a tumor reference center should be contacted for referral or teleradiologic second opinion; this must be done before a biopsy.

9.
Skeletal Radiol ; 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38133670

RESUMO

The diagnosis of prosthetic joint infection (PJI) remains challenging, despite multiple available laboratory tests for both serum and synovial fluid analysis. The clinical symptoms of PJI are not always characteristic, particularly in the chronic phase, and there is often significant overlap in symptoms with non-infectious forms of arthroplasty failure. Further exacerbating this challenge is lack of a universally accepted definition for PJI, with publications from multiple professional societies citing different diagnostic criteria. While not included in many of the major societies' guidelines for diagnosis of PJI, diagnostic imaging can play an important role in the workup of suspected PJI. In this article, we will review an approach to diagnostic imaging modalities (radiography, ultrasound, CT, MRI) in the workup of suspected PJI, with special attention to the limitations and benefits of each modality. We will also discuss the role that image-guided interventions play in the workup of these patients, through ultrasound and fluoroscopically guided joint aspirations. While there is no standard imaging algorithm that can universally applied to all patients with suspected PJI, we will discuss a general approach to diagnostic imaging and image-guided intervention in this clinical scenario.

10.
J Magn Reson Imaging ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37795927

RESUMO

MRI is an expensive and traditionally time-intensive modality in imaging. With the paradigm shift toward value-based healthcare, radiology departments must examine the entire MRI process cycle to identify opportunities to optimize efficiency and enhance value for patients. Digital tools such as "frictionless scheduling" prioritize patient preference and convenience, thereby delivering patient-centered care. Recent advances in conventional and deep learning-based accelerated image reconstruction methods have reduced image acquisition time to such a degree that so-called nongradient time now constitutes a major percentage of total room time. For this reason, architectural design strategies that reconfigure patient preparation processes and decrease the turnaround time between scans can substantially impact overall throughput while also improving patient comfort and privacy. Real-time informatics tools that provide an enterprise-wide overview of MRI workflow and Picture Archiving and Communication System (PACS)-integrated instant messaging can complement these efforts by offering transparent, situational data and facilitating communication between radiology team members. Finally, long-term investment in training, recruiting, and retaining a highly skilled technologist workforce is essential for building a pipeline and team of technologists committed to excellence. Here, we highlight various opportunities for optimizing MRI workflow and enhancing value by offering many of our own on-the-ground experiences and conclude by anticipating some of the future directions for process improvement and innovation in clinical MR imaging. EVIDENCE LEVEL: N/A TECHNICAL EFFICACY: Stage 1.

11.
Cardiovasc Intervent Radiol ; 46(10): 1303-1307, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37668690

RESUMO

Artificial intelligence (AI) has made tremendous advances in recent years and will presumably have a major impact in health care. These advancements are expected to affect different aspects of clinical medicine and lead to improvement of delivered care but also optimization of available resources. As a modern specialty that extensively relies on imaging, interventional radiology (IR) is primed to be on the forefront of this development. This is especially relevant since IR is a highly advanced specialty that heavily relies on technology and thus is naturally susceptible to disruption by new technological developments. Disruption always means opportunity and interventionalists must therefore understand AI and be a central part of decision-making when such systems are developed, trained, and implemented. Furthermore, interventional radiologist must not only embrace but lead the change that AI technology will allow. The CIRSE position paper discusses the status quo as well as current developments and challenges.

12.
Best Pract Res Clin Rheumatol ; 37(2): 101866, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37659890

RESUMO

Osteoarthritis is a complex whole-organ disorder that involves molecular, anatomic, and physiologic derangement. Advances in imaging techniques have expanded the role of imaging in evaluating osteoarthritis and functional changes. Radiography, magnetic resonance imaging, computed tomography (CT), and ultrasonography are commonly used imaging modalities, each with advantages and limitations in evaluating osteoarthritis. Radiography comprehensively analyses alignment and osseous features, while MRI provides detailed information about cartilage damage, bone marrow edema, synovitis, and soft tissue abnormalities. Compositional imaging derives quantitative data for detecting cartilage and tendon degeneration before structural damage occurs. Ultrasonography permits real-time scanning and dynamic joint evaluation, whereas CT is useful for assessing final osseous detail. Imaging plays an essential role in the diagnosis, management, and research of osteoarthritis. The use of imaging can help differentiate osteoarthritis from other diseases with similar symptoms, and recent advances in deep learning have made the acquisition, management, and interpretation of imaging data more efficient and accurate. Imaging is useful in monitoring and predicting the prognosis of osteoarthritis, expanding our understanding of its pathophysiology. Ultimately, this enables early detection and personalized medicine for patients with osteoarthritis. This article reviews the current state of imaging in osteoarthritis, focusing on the strengths and limitations of various imaging modalities, and introduces advanced techniques, including deep learning, applied in clinical practice.


Assuntos
Osteoartrite , Humanos , Osteoartrite/patologia , Radiografia , Ultrassonografia/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
14.
Radiology ; 308(2): e230344, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37606571

RESUMO

CT is one of the most widely used modalities for musculoskeletal imaging. Recent advancements in the field include the introduction of four-dimensional CT, which captures a CT image during motion; cone-beam CT, which uses flat-panel detectors to capture the lower extremities in weight-bearing mode; and dual-energy CT, which operates at two different x-ray potentials to improve the contrast resolution to facilitate the assessment of tissue material compositions such as tophaceous gout deposits and bone marrow edema. Most recently, photon-counting CT (PCCT) has been introduced. PCCT is a technique that uses photon-counting detectors to produce an image with higher spatial and contrast resolution than conventional multidetector CT systems. In addition, postprocessing techniques such as three-dimensional printing and cinematic rendering have used CT data to improve the generation of both physical and digital anatomic models. Last, advancements in the application of artificial intelligence to CT imaging have enabled the automatic evaluation of musculoskeletal pathologies. In this review, the authors discuss the current state of the above CT technologies, their respective advantages and disadvantages, and their projected future directions for various musculoskeletal applications.


Assuntos
Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada Quadridimensional , Extremidade Inferior , Movimento (Física)
15.
Radiology ; 308(2): e230531, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37581501

RESUMO

Over the past decades, MRI has become increasingly important for diagnosing and longitudinally monitoring musculoskeletal disorders, with ongoing hardware and software improvements aiming to optimize image quality and speed. However, surging demand for musculoskeletal MRI and increased interest to provide more personalized care will necessitate a stronger emphasis on efficiency and specificity. Ongoing hardware developments include more powerful gradients, improvements in wide-bore magnet designs to maintain field homogeneity, and high-channel phased-array coils. There is also interest in low-field-strength magnets with inherently lower magnetic footprints and operational costs to accommodate global demand in middle- and low-income countries. Previous approaches to decrease acquisition times by means of conventional acceleration techniques (eg, parallel imaging or compressed sensing) are now largely overshadowed by deep learning reconstruction algorithms. It is expected that greater emphasis will be placed on improving synthetic MRI and MR fingerprinting approaches to shorten overall acquisition times while also addressing the demand of personalized care by simultaneously capturing microstructural information to provide greater detail of disease severity. Authors also anticipate increased research emphasis on metal artifact reduction techniques, bone imaging, and MR neurography to meet clinical needs.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos
16.
Foot Ankle Clin ; 28(3): 463-492, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37536814

RESUMO

Total ankle arthroplasty (TAA) is an effective alternative for treating patients with end-stage ankle degeneration, improving mobility, and providing pain relief. Implant survivorship is constantly improving; however, complications occur. Many causes of pain and dysfunction after total ankle arthroplasty can be diagnosed accurately with clinical examination, laboratory, radiography, and computer tomography. However, when there are no or inconclusive imaging findings, magnetic resonance imaging (MRI) is highly accurate in identifying and characterizing bone resorption, osteolysis, infection, osseous stress reactions, nondisplaced fractures, polyethylene damage, nerve injuries and neuropathies, as well as tendon and ligament tears. Multiple vendors offer effective, clinically available MRI techniques for metal artifact reduction MRI of total ankle arthroplasty. This article reviews the MRI appearances of common TAA implant systems, clinically available techniques and protocols for metal artifact reduction MRI of TAA implants, and the MRI appearances of a broad spectrum of TAA-related complications.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Humanos , Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Imageamento por Ressonância Magnética/métodos , Dor/cirurgia
17.
Foot Ankle Clin ; 28(3): 529-550, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37536817

RESUMO

MRI is a valuable tool for diagnosing a broad spectrum of acute and chronic ankle disorders, including ligament tears, tendinopathy, and osteochondral lesions. Traditional two-dimensional (2D) MRI provides a high image signal and contrast of anatomic structures for accurately characterizing articular cartilage, bone marrow, synovium, ligaments, tendons, and nerves. However, 2D MRI limitations are thick slices and fixed slice orientations. In clinical practice, 2D MRI is limited to 2 to 3 mm slice thickness, which can cause blurred contours of oblique structures due to volume averaging effects within the image slice. In addition, image plane orientations are fixated and cannot be changed after the scan, resulting in 2D MRI lacking multiplanar and multiaxial reformation abilities for individualized image plane orientations along oblique and curved anatomic structures, such as ankle ligaments and tendons. In contrast, three-dimensional (3D) MRI is a newer, clinically available MRI technique capable of acquiring high-resolution ankle MRI data sets with isotropic voxel size. The inherently high spatial resolution of 3D MRI permits up to five times thinner (0.5 mm) image slices. In addition, 3D MRI can be acquired image voxel with the same edge length in all three space dimensions (isotropism), permitting unrestricted multiplanar and multiaxial image reformation and postprocessing after the MRI scan. Clinical 3D MRI of the ankle with 0.5 to 0.7 mm isotropic voxel size resolves the smallest anatomic ankle structures and abnormalities of ligament and tendon fibers, osteochondral lesions, and nerves. After acquiring the images, operators can align image planes individually along any anatomic structure of interest, such as ligaments and tendons segments. In addition, curved multiplanar image reformations can unfold the entire course of multiaxially curved structures, such as perimalleolar tendons, into one image plane. We recommend adding 3D MRI pulse sequences to traditional 2D MRI protocols to visualize small and curved ankle structures to better advantage. This article provides an overview of the clinical application of 3D MRI of the ankle, compares diagnostic performances of 2D and 3D MRI for diagnosing ankle abnormalities, and illustrates clinical 3D ankle MRI applications.


Assuntos
Cartilagem Articular , Fraturas Intra-Articulares , Humanos , Tornozelo , Cartilagem Articular/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tendões , Ligamentos Articulares/diagnóstico por imagem
19.
Skeletal Radiol ; 52(10): 1929-1947, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37495713

RESUMO

The T12 to S4 spinal nerves form the lumbosacral plexus in the retroperitoneum, providing sensory and motor innervation to the pelvis and lower extremities. The lumbosacral plexus has a wide range of anatomic variations and interchange of fibers between nerve anastomoses. Neuropathies of the lumbosacral plexus cause a broad spectrum of complex pelvic and lower extremity pain syndromes, which can be challenging to diagnose and treat successfully. In their workup, selective nerve blocks are employed to test the hypothesis that a lumbosacral plexus nerve contributes to a suspected pelvic and extremity pain syndrome, whereas therapeutic perineural injections aim to alleviate pain and paresthesia symptoms. While the sciatic and femoral nerves are large in caliber, the iliohypogastric and ilioinguinal, genitofemoral, lateral femoral cutaneous, anterior femoral cutaneous, posterior femoral cutaneous, obturator, and pudendal nerves are small, measuring a few millimeters in diameter and have a wide range of anatomic variants. Due to their minuteness, direct visualization of the smaller lumbosacral plexus branches can be difficult during selective nerve blocks, particularly in deeper pelvic locations or larger patients. In this setting, the high spatial and contrast resolution of interventional MR neurography guidance benefits nerve visualization and targeting, needle placement, and visualization of perineural injectant distribution, providing a highly accurate alternative to more commonly used ultrasonography, fluoroscopy, and computed tomography guidance for perineural injections. This article offers a practical guide for MR neurography-guided lumbosacral plexus perineural injections, including interventional setup, pulse sequence protocols, lumbosacral plexus MR neurography anatomy, anatomic variations, and injection targets.


Assuntos
Imageamento por Ressonância Magnética , Bloqueio Nervoso , Humanos , Imageamento por Ressonância Magnética/métodos , Plexo Lombossacral/diagnóstico por imagem , Bloqueio Nervoso/métodos , Extremidade Inferior , Dor
20.
Foot Ankle Clin ; 28(2): 231-264, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37137621

RESUMO

Acute ankle sprains are common sports injuries. MRI is the most accurate test for assessing the integrity and severity of ligament injuries in acute ankle sprains. However, MRI may not detect syndesmotic and hindfoot instability, and many ankle sprains are treated conservatively, questioning the value of MRI. In our practice, MRI adds value in confirming the absence or presence of ankle sprain-associated hindfoot and midfoot injuries, especially when clinical examinations are challenging, radiographs are inconclusive, and subtle instability is suspected. This article reviews and illustrates the MRI appearances of the spectrum of ankle sprains and associated hindfoot and midfoot injuries.


Assuntos
Traumatismos do Tornozelo , Traumatismos em Atletas , Entorses e Distensões , Humanos , Entorses e Distensões/diagnóstico por imagem , Entorses e Distensões/terapia , Traumatismos em Atletas/diagnóstico por imagem , Traumatismos em Atletas/terapia , Ligamentos Articulares , Imageamento por Ressonância Magnética , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...